Answer
Mar 25, 2025 - 06:23 AM
Including or excluding Z-Wave devices like the Fibaro Button can be tricky, so you may need to try several times. Timing is crucial when pressing the B-Button, as it requires a quick triple-click; clicking more than three times cancels the process. It might help to first exclude the device, then immediately include it. If you have a momentary switch attached to the S1 switch input, you can use it for the triple-click to make timing easier. If you have a toggle switch attached to the S1 input, leave it in the OPEN position while trying to exclude/include the device. Some Fibaro modules support "power on Inclusion," automatically entering inclusion mode when powered on. Try turning off the power, putting your Z-Wave controller into inclusion mode, and then turning the power back on to see if the Fibaro Button includes correctly without further effort.