Thousands of Happy Smart Home Customers

But don’t just take our word for it...

We offer great products & great knowledge all backed up with great service - and our customers agree!

We’re very proud of our independent Excellent Trustpilot rating, backed up by the many repeat customers we’ve been supporting for years.

 

Read More

 
 

World-Class, Industry-Leading Technical Support - Forever Free

You’ll always have FREE access to our technical knowledgebase, application guides, YouTube tutorials & Customer Services, as well as all other online resources, help, white papers and articles.

If none of these answer your query you can also raise a ticket and get direct access to our team of smart home specialists for for assistance.

 
 

Access to technical specialists
100’s of in-depth help resources
Video guides via YouTube channel
Blog articles with product reviews & test results

 
 

The Vesternet Promise

As Founder & CEO of Vesternet, I personally guarantee your 100% satisfaction on any purchase.

I’d never want you to be unhappy with something you buy from us, so here’s my promise - you can return any unused products within 365 days. If you have problems with a new purchase, our support team will work with you to resolve. And if you still can’t get it working then you can return it within 14 days for replacement or refund. For full information take a look at our full returns policy.

In addition, here’s my personal email should you ever have any problems or feedback: dave.bell@vesternet.com

We’re not just a shop, we’re with you all the way on building your smart home.

 
 

Z-Wave Compatibility Guide

This guide shows the Z-Wave products that have been tested by Vesternet and our customers. They are known to work well.

Even though Z-Wave is a standard, different vendors use different parts of the standard. This means that choosing devices to work together as a system can be full of problems. We've put together this guide to show which products we know work well together, it's not a comprehensive list, but one based on the most popular products from our range.

We will update it regularly and appreciate any feedback you can provide to make this guide more accurate and up to date, email us at feedback@vesternet.com

NOTE: Please make sure to check the software version of your Z-Wave controller when referring to this list!

Z-Wave Compatibility Guide

Product Part # VERA 12 ZipaBox 12 Fibaro 12 3rd Party Controllers Comments
(UI5 / UI7 / Edge) (HC2 v4.x / HC2 v3.5 / HCL v3.5) (Homeseer / Indigo / Domoticz / SmartThings)  
Lighting and Sockets
AEON Labs Heavy Duty Switch AEO-HDS 49 / 84 / 64 / 47 / 47 - / - / - / -   Vesternet 3-wire Icon Vesternet Z-Wave Plus Icon
AEON Labs Micro Dimmer AEO-MEI / - / - / / / / /   Vesternet 3-wire Icon  
AEON Labs Micro Switch AEO-MES / - / - / / / / / -   Vesternet 3-wire Icon  
AEON Labs Micro Smart Energy Dimmer AEO-MSEI / - / 3 - / / / / /   Vesternet 3-wire Icon  
AEON Labs Micro Smart Energy Switch AEO-MSES / - / 3 - / / / / /   Vesternet 3-wire Icon  
AEON Labs Smart Energy Switch 3 Gen5 AEO-SES3 56 / 105 / 64 98 / / - / - / - /     Vesternet Z-Wave Plus Icon
Domitech Dimmable Smart LED Light Bulb DOMEZBULB-DOMEZBULB-UK 121 / 129 / 64 127 127 / 127 / 127 - / - / - / -     Vesternet Z-Wave Plus Icon
Everspring Dimmer Plug EVR_AD142 / / - / / / / / -   Vesternet 3-wire Icon  
Everspring On/Off Plug EVR_AN157 / / - / / 16 / / / -   Vesternet 3-wire Icon  
Everspring On/Off Plug with power meter EVR_AN158 / / - / / 16 / / / -   Vesternet 3-wire Icon  
Everspring Screw-In Lamp Holder EVR_AN145 / / - / / / / / -   Vesternet 3-wire Icon  
Fibaro 1x3KW Relay FGS-211 / - / - / / / / / -   Vesternet 3-wire Icon  
Fibaro 2x1.5KW Relay FGS-221 / - / - / / - / / / -   Vesternet 3-wire Icon  
Fibaro Relay Insert 1 * 2.5 KW FIBEFGS-212 / - / - / / / / / -   Vesternet 3-wire Icon  
Fibaro Relay Insert 2 * 1.5 KW FIBEFGS-222 / - / - / / - / / / -   Vesternet 3-wire Icon  
Fibaro Roller Shutter 2 FGRM-222 / - / - / / - / / / -   Vesternet 3-wire Icon  
Fibaro RGBW Controller FGRGB-101 / / - / / / 37 / / -      
Fibaro Universal Dimmer FGD-211 / - / 2 - / / / / /   Vesternet 2-wire Icon  
Fibaro Universal Dimmer 2 250W FIBEFGD-212 - / - / - - - / - / - - / - / - / -   Vesternet 2-wire Icon Vesternet Z-Wave Plus Icon
Fibaro Wall Plug FGWPF-101 / / - / / - / / / -   Vesternet 3-wire Icon  
Greenwave 1 Port PowerNode NS210-G-EN / 84 / 64 83 / / - / / - / -      
Greenwave 5 Port PowerNode NP210-G-EN 85 / 86 / 87 123 / 88 / 88 - / / / -      
MCO 2-Channel Switch MCO_TPS312 / / / / - / - / - / -   Vesternet 3-wire Icon  
MCO 4-Channel Switch MCO_TPS314 / / / / - / - / - / -   Vesternet 3-wire Icon  
Popp On/Off Plug POP_123xxx / / - / / - / / / -   Vesternet 3-wire Icon  
Popp Dimmer Plug POP_123xxx / / - / / - / / / -   Vesternet 3-wire Icon  
Popp Wall Plug Switch/Meter POP_123665-58 / / - / / - / / / -   Vesternet 3-wire Icon  
Philio 2 x 1.5Kw Relay with Power Measurement PAN04 29 / - / - / 30 / 30 - / 31 / / -   Vesternet 3-wire Icon  
Philio 2 x 1.5Kw Relay PAN06 29 / - / - / 30 / 30 - / 31 / / -   Vesternet 3-wire Icon  
Philio Blind Control PAN08 29 / - / - / 30 / 30 - / 31 / / -   Vesternet 3-wire Icon  
Qubino Flush Dimmer ZMNHDA2 76 / 76 / 76 76 / 77 / 77 / / / -   Vesternet 3-wire Icon  
Qubino Flush Relay x 1 ZMNHAA2 76 / 76 / 76 76 / 77 / 77 / / / -   Vesternet 3-wire Icon  
Qubino Flush Relay x 2 ZMNHBA2 76 / 76 / 76 90 / 78 / 78 / / / -   Vesternet 3-wire Icon  
Qubino Flush 1D Relay ZMNHND1 - / - / - - / - / - - / - / - / -   Vesternet 3-wire Icon  
Qubino Flush Shutter ZMNHCA2 / / / / / / / -   Vesternet 3-wire Icon  
Qubino Flush Shutter DC ZMNHOD1 - / - / - - / - / - - / - / - / -   Vesternet 3-wire Icon  
SwiidInter Cord Switch SW-ZCS-1 / / / / - / - / - / -   Vesternet 3-wire Icon  
TKB Dimmer Plug TZ67 / / / / / 15 / / -   Vesternet 3-wire Icon  
TKB On/Off Plug TZ68 / / - / / / 15 / / -   Vesternet 3-wire Icon  
TKB Wall Plug Switch/Meter TZ88 / / 81 / / 38 / / / -   Vesternet 3-wire Icon  
TKB On/Off Switch Insert TZ76 / - / - / / / / / -   Vesternet 3-wire Icon  
Zipabox RGBW LED Bulb RGBWE39ZW 46 / - / 46 - / 59 / 59 - / - / - / -      
Sensors
AEON Labs Door/Window Sensor AEO_DSC20-EU / - / - / / - / - / - /      
AEON Labs Recessed Door Sensor AEO_DSB54 / / - / / - / - / - /      
AEON Labs Recessed Door Sensor Gen5 AEO_ZW089 56 / - / 64 107 / 58 / 58 - / - / - /     Vesternet Z-Wave Plus Icon
AEON Labs Multisensor AEO_MULTISENS / - / - / / / 15 / - /      
AEON Labs Multisensor Gen5 AEOEZW074 56 / - / 64 / 58 / 58 - / - / - /     Vesternet Z-Wave Plus Icon
AEON Labs Clamp Meter 40 AEO-HEM2, HEM3 32 / - / 55 - / / - / 15 / -      
AEON Labs Siren Gen5 AEO_DSD31 53 / / 60 106 / 54 / 54 - / - / - /     Vesternet Z-Wave Plus Icon
Everspring Door/Window Detector EVR_HSM02 / - / - / / / / -      
Everspring Motion Detector EVR_HSP02 / - / - / 14 / 14 - / - / - / -      
Everspring Motion Sensor EVR_SP103 / - / - / / - / / - /      
Everspring Motion Detector EVR_SP814 / / - / 14 / 14 - / / - / -      
Everspring Siren EVR_SE812 / - / / / - / / - / -      
Everspring Smoke Detector EVR_SF812 / - / - / / - / / - / -      
Everspring Temperature & Humidity Sensor EVR_ST814 / / - / / / / -      
Fibaro Door/Window Sensor FGK-001 / - / - / / - / 15 / - /      
Fibaro Flood Sensor FGFS-101 / - / - / / - / / - /      
Fibaro Motion Sensor FGMS-101 34 / 51 / 51 - / / - / 37 / - /      
Fibaro Smoke Sensor FGSS-101 28 / 80 / 80 - / / - / / - / -      
Fibaro Smoke Sensor Plus Gen5 FGSD-002 / - / 64 98 / 58 / 58 - / - / - / -     Vesternet Z-Wave Plus Icon
Fibaro Universal Sensor FGBS-001 / - / - / / / / - / -      
North-Q Data-Logger - Electric Meter NQ9021 / - / - - / / - / - / - / -      
North-Q Data-Logger - Gas Meter NQ9121 / - / - - / / - / - / - / -      
Popp Smoke Detector and Temp Sensor POP_004308 / - / 41 82 / 42 / 61 - / - / - / -      
Philio 4-in-1 (PIR, Door, Light, Temp) PSM02 25 / - / - / 26 / 65 - / 31 / - / -      
Philio 3-in-1 (Door, Light, Temp) PSM01 / - / - / 27 / 66 - / 31 / - / -      
Philio 3-in-1 Sensor (PIR, Light, Temp) PSP01 / - / - / 27 / 66 - / 31 / - / -      
Philio 4-in-1 (PIR, Door, Light, Temp) Gen5 PST02-1A 91 / - / 99 109 / 58 / 58 - / - / - / -     Vesternet Z-Wave Plus Icon
Philio 3-in-1 (Door, Light, Temp) Gen5 PST02-1C 91 / - / 99 - / 58 / 58 - / - / - / -     Vesternet Z-Wave Plus Icon
Philio 3-in-1 (PIR, Light, Temp) Gen5 PST02-1B 91 / - / 99 - / 58 / 58 - / - / - / -     Vesternet Z-Wave Plus Icon
Sensative Strips Door/Window Sensor 312297 - / 130 / 130 - / - / - - / - / - / -     Vesternet Z-Wave Plus Icon
Vision CO Detector VIS_ZS6301 / - / - / / - / / - / -      
Vision Door/Window Sensor VIS_ZD2102 / - / - - / / - / / - / -      
Vision Garage Door Detector VIS_ZG8101 / - / - / / - / / - / -      
Vision Motion Detector VIS_ZP3102 22 / - / 22 - / 33 / 33 - / / - / -      
Vision Shock & Vibration Sensor VIS_ZS5102 / - / - / / - / / - / -      
Vision Siren (Battery) VIS_ZM1601 / / - / / - / / - / -      
Vision Siren (Mains) VIS_ZM1602 / / - / / - / / - / -      
Vision Smoke Detector VIS_ZS6101 / - / - / / - / / - / -      
Thermostats, Heating & Cooling
Danfoss Thermostat Radiator Valve DAN_LIVC_RAK (014G0012) / - / - - / / / / - / -      
Danfoss Thermostat Radiator Valve DAN_LC-13 (014G0013) / 50 / 50 / / / / - / -      
Danfoss Room Thermostat DAN_RS-Z - / - / 102 - / - / - - / - / - / -    
Heatit Wall Thermostat (Black) 5430498 67 / 68 / 68 70 / 69 / 69 - / - / - / -     Vesternet Z-Wave Plus Icon
Heatit Wall Thermostat (White) 5430499 67 / 68 / 68 70 / 69 / 69 - / - / - / -     Vesternet Z-Wave Plus Icon
Netatmo Intelligent Wi-Fi Thermostat NTH01-FR-EC / / / / - / - / - / -      
Qubino Flush Thermostat ZMNHIA2 / - / 101 - / 96 / 96 - / - / - / -      
Qubino Flush Heat And Cool Thermostat ZMNHKA2 - / - / - - / - / - - / - / - / -      
Qubino Flush PWM Thermostat ZMNHLA2 - / - / - - / - / - - / - / - / -      
Remotec AC-IR Extender ZXT-120 / - / / / - / - / - / -      
Secure RF Countdown Timer SIR321 100 / - / 100 - / 97 / 97 - / - / - / -      
Secure Wall Thermostat SRT321 (HRT4-ZW) / 50 / 50 / / 13 / / - / -      
Secure Boiler Receiver SSR303 (ASR-ZW) / / - / / 13 / / / -      
Secure Thermostat & Receiver Set SRT322 / 50 / 50 / / 13 / / - / -      
Secure 2-Channel Receiver SSR302 (ASR2-ZW) / / 122 / / / / - / -      
Secure Temperature Sensor SES301 / - / - / / / / - / -      
Secure 7-day Programable Room Thermostat SCS317 / 50 / 50 - / / - / / / -      
Secure Timer Controller Wall Thermostat 19 STP328 / / / / / / / -      
Secure 7 Day Time Controller 19 SCP318 / / / / / / / -      
StellaZ Thermostat Radiator Valve STELLAZ / 50 / 50 110 / 23 / 23 - / / - / -      
Controllers
Aeon Labs Extender AEO_EXTENDER / / / - / / / / -      
Aeon Labs Key Fob AEO_KFOB / - / - 35 / 35 / 36 - / / - /      
Aeon Labs Key Fob Gen 5 AEO_ZW088 92 / - / 56 / 35 / 36 - / - / - /     Vesternet Z-Wave Plus Icon
AEON Labs MINIMOTE AEO_MREM / - / 6 35 / 35 / 36 / / - /      
Aeon Labs Series 2 USB Controller AEO_USB - / - / - - - / - / - / / / -      
Aeon Labs Z-Stick USB Controller Gen5 AEOEZW090-C - / - / - - - / - / - / / / -     Vesternet Z-Wave Plus Icon
Duwi Remote Control 71 DUW_064459 / - / - / / / / - / -      
Nodon Octan Remote Gen5 CRC-3-1-00 121 / 116 / 115 117 118 / 120 / 119 - / - / - / -     Vesternet Z-Wave Plus Icon
Nodon Soft Remote Gen5 CRC-3-6 121 / 116 / 115 117 118 / 120 / 119 - / - / - / -     Vesternet Z-Wave Plus Icon
Nodon Wall Switch Gen5 CWS-3-1 121 / 116 / 115 117 118 / 120 / 119 - / - / - / -     Vesternet Z-Wave Plus Icon
Z-Wave.me Remote Control RC2 ZME_RC2 56 / - / 102 - / 95 / 93 - / - / - / -      
Zipabox RFID Keypad WT-IRFID-EU 44 / - / 57 - / 45 / 45 - / - / - / -      
Z-Wave.me Labs Key Fob ZME_KFOB2 / - / 64 - / / 36 / / - / -      
Z-Wave.me Labs Key Fob Gen5 ZME_KFOB-S 92 / - / 56 108 / 94 / 94 - / - / - / -   Vesternet Z-Wave Plus Icon
Z-Wave.me Wall Controller Set Gen5 ZME_WALLC_SET 92 / 103 / 104 35 / 58 / 58 - / - / - / -     Vesternet Z-Wave Plus Icon
Z-Wave.me Wall Controller Single BJ2000 WCS1-S2 / - / - - / / 36 / / - / -      
Z-Wave.me Wall Controller Double BJ2000 WCD1-D2 / - / - - / / 36 / / - / -    
Multimedia
iTach TCP/IP to IR IP2IR / - / 63 - - / / - / / - / -      
iTach TCP/IP to IR PoE IP2IR-P / - / 63 - - / / - / / - / -      
iTach Wi-Fi to IR WF2IR / - / 63 - - / / - / / - / -      
iTach TCP/IP to Serial IP2SL - / - / - - - / / - - / / - / -      
iTach TCP/IP to Serial PoE IP2SL-P - / - / - - - / / - - / / - / -      
iTach Wi-Fi to Serial WF2SL - / - / - - - / - / - - / / - / -      
iTach TCP/IP to Contact Closure IP2CC / - / - - - / - / - - / / - / -      
iTach TCP/IP to Contact Closure PoE IP2CC-P / - / - - - / - / - - / / - / -      
iTach Wi-Fi to Contact Closure WF2CC / - / - - - / - / - - / / - / -      
iTach Flex IP FlexIP / - / 63 - / / - / / - / -      
iTach Flex Wi-Fi FlexWF / - / 63 - / / - / / - / -    
Locks
Poly-Control Dana Lock - Circle POL_BTZEC100 / / - / 11 / 11 - / - / - /      
Vision Door Lock VIS_ZM1702 / - / - / 11 / 11 - / - / - / -      
Yale Smart Living Keyless Connected Smart Lock 126 YD-01-CON-CH / - / 124 125 / 11 / 11 - / - / - /      
Yale Smart Living Keyfree Connected Smart Lock 126 YKFCON / - / 124 125 / 11 / 11 - / - / - /      
Other
Netatmo Connected Weather Station NWS01-WW 73 / 74 / 74 73 / / - / - / - / -      
Netatmo Additional Module 75 NIM01-WW 73 / 74 / 74 73 / / - / - / - / -      
Netatmo Rain Gauge 75 NRG01-WW 73 / 74 / 74 73 / / - / - / - / -      
Popp IP Camera POP_003103 43 / - / 72 - / / - / - / - / -      
Popp Weather Station Gen5 POPE005206 111 / 112 / 113 114 / - / - - / - / - / -     Vesternet Z-Wave Plus Icon
RFXtrx433E Transceiver RFXtrx433E (14103) / / 62 7 / / / / / -      
ZipaBox Wall Tablet With Wall Station 79 ZIP-WTAB7V1 / / / / / / / -      

Definitions

Tested by Vesternet. Fully compatible with the controller and other devices on the network. Controller can Include, control and access any advanced functions of the device.
1 Tested by Vesternet. Can be Included into network but not all functions are supported by the controller. Details are given in the notes (1) section.
1 Device tested by numerous customers and shown to have no compatibility issues, more information given in notes (if available).
1 Not compatible with the controller. Not a recommended combination. Further notes provided.
- Not tested - we would like user feedback about this device's compatibility with your controller. Contact us at feedback@vesternet.com.
2-Wire. This product works in a 2-wire system and does not require neutral, more information is available at Understanding 2-wire and 3-wire Lighting Systems.
3-Wire. This product works in a 3-wire system and requires neutral, more information is available at Understanding 2-wire and 3-wire Lighting Systems.
Z-Wave Plus Certified - More information in What is Z-Wave Plus?.

Notes 

1. Installs correctly but can only be controlled On/Off. Currently no power monitoring or measurement information is displayed.
2. Installs correctly and all functions available. Sensors cannot be directly associated with the dimmer, you must use rules in the Zipato Rule Creator.
3. Installs and works correctly. Power is displayed in 'Meters' widget and in the Current value widget, but does not display in the 'Power Gauge'.
This will be corrected in a new Zipato firmware release.
6. Currently not compatible with ZipaBox.
7. Requires ZipaBox Back-up module (USB connection).
8. Not compatible with the Fibaro HC2.
9. Works in a 2-wire lighting system, no Neutral required. See APNT-1.
10. Requires a 3-wire system, including Neutral. See APNT-17.
11. Security commands for locks not currently supported in HC.
12. Unless otherwise mentioned, controller Software Versions used for testing are as follows:
  • VERA: UI5 - v1.5.622
  • VERA: UI7 - v1.7.439
  • VERA: Edge - v1.7.906
  • ZipaBox: v0.9.972
  • HC2: V3 - v3.590
  • HC2: V4 - v4.019
  • HCL: v3.593
13. Tested using Aeon USB 2 USB Controller.
14. Configuration parameters cannot be set in HC2 or HCL.
15. Tested with Indigo v6 build 8.
16. Only supports polling (not association for updates).
17. Supports On/Off but not setpoint control.
18. Must be used with VERA 1.5.622 or later and latest device file patches - see APNT-37.
19. This device cannot be controlled by other Z-Wave devices except the Secure Wall Thermostat. It cannot be included into a Z-Wave network that is controlled by a Z-Wave controller.
20. Not recommended to be used with HC2.
21. Can be added to Zipabox, but currently Zipabox cannot control it or make setpoint changes.
22. See KB-47 for details.
23. Can be added to HC2 and HCL, but currently HC2 or HCL cannot control it or make setpoint changes.
24. Only Motion sensor displays in HC2 and HCL - temperature and light sensors are not accessible.
25. Motion and Door sensors are combined in 1.5.622, see APNT-55.
26. Motion and Door sensors are combined and light sensor is not accessible in scenes. Temperature sensor can be used in LUA.
27. Light sensor is not accessible in scenes. Temperature sensor can be used in LUA.
28. Requires VERA 1.5.672 (Beta) or later. Not supported in VERA UI5 (1.5.622) - See KB-10 for details. Temperature sensor doesn't show as separate device, only accessible from LUA.
29. Requires VERA MIOS Update to be run to enable it to work correctly in VERA 1.5.622.
30. Will include into HC2 and HCL, but only the parent device will work - you cannot control each channel separately. Will be supported in future HC firmware release.
31. Requires Indigo v6.0.11 or later.
32. G2 version of the clamp requires VERA MIOS Update Utility and corrected configuration - see KB-48. Note only 1-clamp version tested as we can only test this version on single phase mains supplies.
33. Only Motion sensor displays - temperature sensor is not accessible.
34. Sensor v2.6 works in VERA UI5 (requires 1.5.672 beta) - See VERA and Fibaro Motion Sensor compatibility issue. Note: sensor v2.4 does not work in VERA at all.
35. Can control devices via Association. Can use as scene controller by using LUA scripting. See APNT-42 for further details.
36. Can control devices via Association. Does not work as scene controller as this requires LUA scripting.
37. Requires Indigo v6.0.12 or later.
38. Requires Homeseer v2.5.0.81 or later.
40. Only 1-clamp version tested as we can only test this version on single phase mains supplies.
41. Installs as Smoke sensor only - you can use Smoke = True in Rule Creator.
42. Installs as motion sensor (can be changed) and works in scenes. Temperature reading shows in icon but can only be accessed in scenes using LUA.
43. Installs as Foscam - need to use Foscam plug-in.
44. Installs correctly and can be used as a PIN entry for scenes, but can only use a single RFID tag (need to install plugin to use RFID tag).
45. Installs as unknown device - no way to add PIN numbers.
46. See APNT-91.
47. Does not display Energy Usage in HC / HCL.
48. Cannot be added (included) to Zipato.
49. Requires v1.5.672 Beta - more information in APNT-89.
50. In UI7 setpoint can be changed in scenes but does not allow you to enter a specific value in the device's UI Icon. Set-point transmission to device seems intermittent at best and doesn't always follow configured wake-up period.
51. v2.6 or greater installs correctly, displays motion, temperature and light sensor icons. Lux displays as percentage (%). Scene cannot use Brightness below.
53. Requires v1.5.672 Beta. See APNT-90 for details on controlling the different sounds.
54. Installs correctly but cannot change siren sounds dynamically, only via configuration.
55. Installs as parent and child device (1-clamp version). Parent displays W and KWh, but child only displays KWh, but as single clamp version that should not matter as parent displays correct values.
56. Installs with difficulty - contact us for further information!
57. Recognised in wizard and installs correctly as a keypad. Integrated into UI7's 'Home and Away' modes. Currently the RFID tag plugin does not work, meaning it's not possible to use the RFID tags.
58. Includes as an un-recognised device, not functional at all.
59. Can only control White LED channel - cannot control RGB channels.
60. See APNT-90 for details on controlling the different sounds.
61. Installs as motion sensor (can be changed) and works in scenes. Temperature reading shows in icon but can't be accessed from Scenes as this requires LUA.
62. See KB-60 for details.
63. Requires modified GC100 plugin files - contact us for further information!
64. Tested in v1.7.1018.
65. Motion and Door sensors are combined and neither light sensor nor temperature sensor are accessible in scenes.
66. Light sensor and temperature sensors are not accessible in scenes.
67. Requires v1.5.672 Beta - See here for download information. Only possible to change set-point when device is in CO mode. Only CO and OFF modes are available.
68. Only possible to change set-point when device is in CO mode. Only CO and OFF modes are available.
69. Only possible to change set-point when device is in CO mode. Can't change the mode at all. Set-point reading periodically fluctuates between showing CO and ECO data. Temperature reading periodically fluctuates from 0 to actual to 255.
70. Can only change set-point from scenes or the heating panel when device is in CO mode. Can't change the mode from a scene or the heating panel.
71. See KB-37 for details.
72. Install as "VistaCamP/T". P/T controls can work after adding new implementation file, contact us for further information!
73. Install plugin from App Store.
74. Install plugin from App Store. Requires updated files for UI7, see Vera forum for more details.
75. Additional modules require main Netatmo weather station too.
76. Temperature sensor doesn't show as separate device, only accessible from LUA.
77. Temperature sensor doesn't show as separate device, mixed in with power consumption data. Binary sensors not functional.
78. Temperature sensor doesn't show as separate device. Installs as two devices, one controls BOTH relays, the other controls the second relay.
79. Works with a variety of Android Apps - both official and third party. Simply visit the Google Play store and install your choice of App!
80. Tested in v1.7.1018. Temperature sensor doesn't show as separate device, only accessible from LUA.
81. Parameters and Associations can't be saved.
82. Shows as two devices, motion and temperature. Temperature device never updates.
83. kWh reading did not seem to increase over time.
84. Tested in 1.7.541.
85. Can control each socket indvidually from UI. Does not show power consumption on indvidual devices in UI. Device 1 in UI shows power consumption of ALL sockets.
86. Tested in 1.7.541. Can control each socket indvidually from UI. Does not show power consumption on indvidual devices in UI. Device 1 in UI shows power consumption of ALL sockets.
87. Tested in 1.7.1018. Can control each socket indvidually from UI. Does not show power consumption on indvidual devices in UI. Device 1 in UI shows power consumption of ALL sockets.
88. Can control each socket indvidually from UI. Does not show power consumption on indvidual devices in UI.
89. Would not Include, Inclusion process kept timing out.
90. Only shows power consumption for whole device, not individual channels.
91. Requires v1.5.672 Beta - See here for download information. Only light and temperature parts work, UI5 does not react to motion sensor or magentic sensor events.
92. Requires v1.5.672 Beta - See here for download information. Installs with difficulty, contact us for further information!
93. Can only use with Associations, but is easy to configure from controller UI and works well with most dimming and on / off devices.
94. Includes correctly but HC can't complete configuration, does not recognise wake-up from device.
95. Can use with Associations or Advanced Scenes using LUA to process the Scene IDs similar to the guide here.
96. Temperature data not shown in UI. No way to change heating mode from controller - can only send set-point changes from Heating Panel IF the device is already turned to Auto mode locally.
97. Can control on / off from UI which sets countdown to 120 minutes. Optional temperature sensor shown in UI but not usable in Scenes from graphical scene builder (HC2 & HCL) nor using LUA (HC2).
98. Tested in 4.047.
99. Tested in 1.7.1018. All sensors available individually working fully out-of-the-box. Spurious parent icon in UI shows non-functional Generioc IO device. Tamper alerts not functional.
100. Tested in 1.7.1018. Can control on / off from UI which sets countdown to 120 minutes. Optional temperature sensor not shown in UI but accessible via LUA.
101. Tested in 1.7.1018. Does not show power consumption data in UI.
102. Tested in 1.7.1018. Installs with difficulty - contact us for further information!
103. Tested in 1.7.599. New "Central Scenes" capability in latest firmware allows device to work correctly for basic Scene Triggers - contact us for further information!
104. Tested in 1.7.1181. New "Central Scenes" capability in latest firmware allows device to work correctly for basic Scene Triggers - contact us for further information!
105. Tested in 1.7.599.
106. Tested in 4.042. Associations not working, cannot change siren sounds dynamically, only via configuration.
107. Tested in 4.042.
108. Tested in 4.042. Includes correctly but HC can't complete configuration, does not recognise wake-up from device.
109. Tested in 4.042. Motion and Door sensor functions combined into one device in UI, no way to distinguish them apart.
110. Tested in 4.042. Can't change set-point.
111. Requires v1.5.672 Beta - See here for download information. Only temperature, light level and humidity level devices are working in UI.
112. Tested in 1.7.541. Only temperature, light level and humidity level devices are working in UI.
113. Tested in 1.7.1018. Only temperature, light level and humidity level devices are working in UI.
114. Tested in 4.047. Only temperature device is working in UI.
115. Tested in 1.7.1248.
116. Tested in 1.7.619.
117. Tested in 0.9.999.6.
118. Tested in 4.049.
119. In 3.594 will only work with Association (no Scene Controller support in 3.594). In 4.044 works with Scene Activation in Block Scene Builder and / or Associations.
120. Can use with Associations or Advanced Scenes using LUA to process the Scene IDs similar to the guide here.
121. Requires v1.5.672 Beta - See here for download information.
122. Tested in 4.049. Can control each channel from UI but not Scene Builder or Heating Panel. Can use LUA scripting to control each channel.
123. Tested in 4.040.
124. Tested in 1.7.1419.
125. Tested in 4.056. Note only basic lock / unlock functionality is working.
126. Requires Z-Wave Home Automation Module option.
127. Tested in 4.040. UI has issue with tracking dimming level status.
128. UI has issue with tracking dimming level status.
129. Tested in 1.7.569.
130. Tested in 1.7.1598. Requires workaround to operate correctly, see APNT-108 for further details.

Related Information

Vesternet Application Notes

Feedback

We plan to keep this compatibility guide as up to date as possible, but we encourage you to give your feedback as well.

If you would like to see other devices added or you've tested devices and would like to tell people about them - then let us know.

Contact us at feedback@vesternet.com


 

Vesternet is Europe’s leading home automation specialist. We offer a comprehensive range of Z-Wave and other home automation products. Our sales and support staff are fully trained to help you to select the best Z-Wave product for your application.

Copyright Vesternet 2015

Updated: 18/12/15

You viewed

Please wait...

Item(s) Added Continue shopping or View cart & checkout
Continue shopping or View cart & checkout