I am currently using these with 240v halogen bulbs and wanted to switch to LED. In some places it will be 3 wired and in others I will add a bypass unit. Is there any particular brands of dimmable 240v LED bulbs that people have had success or problems with? Or am I pretty safe just going with shop own brand? They would be either E27 golfball bulbs or gu10 spots View answer
Asked 8 ´years ago | Z-Wave Fibaro Universal Dimmer 2
I was seriously thinking about buying one of these for a house I am buying off plan but put off by the fact that this cannot be installed in direct sunlight and needs to be protected from rain. How can this be used as an external door entry system if it can’t be used outside? Also, with the camera, can I hook this up to an NVR to record the live stream like a CCTV camera? If the above can be confirmed, that would be great! Thanks, Hal View answer
Asked 8 ´years ago | Fibaro Intercom
If you were using 3-position (on/off/on) switches would you need 3core+ earth cable running between all switches in a 2-way or multi-way lighting circuit? or could this be achieved with 2 core+earth cable between switches? thanks View answer
Asked 8 ´years ago | Z-Wave Fibaro Universal Dimmer 2
When using the Dimmer 2 in a 2-way or multi-way circuit, do the momentary (bell-push) switches need to be 2-way switches or will 1-way switches work? (as the wiring is simplified when using momentary switches). Such as the Varilight 2-Gang 6A 1-Way Push-to-Make Momentary Switch? Thanks View answer
Asked 8 ´years ago | Z-Wave Fibaro Universal Dimmer 2
I bought this motion sensor and tried without success to include to my new smartthings hub v2 (UK version). Smartthings support advised me to confirm that the motion sensor is also a UK version (not a US one), as apparently the frequencies are different... Can you please confirm that this sensor works with the UK version of smartthings hub? View answers
Asked 8 ´years ago | Z-Wave Fibaro Multi Sensor
Hi. Has anyone had a good experience with these? The concept is great, but not if it doesn't work! Is it the firmware that is unstable, or the controller software? Have the Vesternet staff had any experience with them? Also, are they always listening, or do they have a wake up period? Thanks, Ed View answers
Asked 8 ´years ago | Z-Wave Fibaro Heat Controller
I have a Homeseer setup and have bought the Fibrao FGS 223. I have managed to include it but want to change the default toggle to momentary switch as that's what I have elsewhere [legacy X10]. I tried Setting Parameter 20 to 0 in homseer z-wave node but it just says error and dosent change. Any help please View answer
Asked 8 ´years ago | Z-Wave Fibaro Double Switch 2
Hi Folks. Is it feasible to use this sensor to control your central heating. If I used a fibaro relay to control the boiler could the temperature sensor be used as a thermostat to set or monitor the temperature or would I need to buy a dedicated Zwave thermostat? Any advice would be greatly appreciated. View answer
Asked 8 ´years ago | Z-Wave Fibaro Multi Sensor
How does the thermostat in a room that is too cold turn the boiler on so that the radiator can be supplied with hot water. You can’t leave the boiler set on permanently. In most UK central heating systems there is a central thermostat and or programmer that determines when the boiler switches on or off. View answers
Asked 9 ´years ago | Z-Wave Fibaro Heat Controller
Asked 9 ´years ago | Z-Wave Fibaro Multi Sensor
Hi all, I have installed a couple of these (fgs223) on a 2 way switch. One is an on off switch and the other is a dimmer. I've put the switches behind the on off switch. That bit works well but now the separate dimmer won't dim it only switches on and off. Any suggestions? View answers
Asked 9 ´years ago | Z-Wave Fibaro Double Switch 2
Z-Wave Fibaro KeyFob working with the Vera plus ?
Asked 9 ´years ago | Z-Wave Fibaro KeyFob
Has this been proven to work with HomeSeer?
Asked 9 ´years ago | Z-Wave Fibaro Button
How many 240V GU10 Led Bulbs (Dimmable ones) can the FD2 support? I have 3 light fittings for outside my house that house 2 GU10 240 Bulbs or GU10 240V Dimmable Bulbs. I am going to use the LED Dimmable bulbs which on the box say "Use only 7 watts per bulb". So a total of 6 bulbs in 3 light housings. I'm going to wire them back to a junction box in parellel (not serial) and into then into the FB2 but was worried that 6 bulbs of this type (or even 10) would fry it? I have the original Fibaro Bypass Module also (FGB001) which I bought a few years ago but never used, could I use this if I need it? The LED 240v GU10 bulbs are "dimmable" Thanks! Andy View answers
Asked 9 ´years ago | Z-Wave Fibaro Universal Dimmer 2
Does this need ventilation? I was planning on using these in the loft for the upstairs lighting and putting them in PVC boxes along with any connectors etc. This is to keep things neat and safe but wondered if I need to drill holes in the boxes for ventilation? View answers
Asked 9 ´years ago | Z-Wave Fibaro Universal Dimmer 2
What's the difference between this model (FIBEFGS-223) and the FIBEFGS-222? One is described as a switch and the other as a relay, but otherwise seem identical. Does it make any difference to what it can do? I want to use them behind existing light switches to control lighting circuits - does it make any difference which I use? Thanks! View answers
Asked 9 ´years ago | Z-Wave Fibaro Double Switch 2
Does this device work fully with HomeSeer? View answer
Asked 9 ´years ago | Z-Wave Fibaro Double Switch 2
Would there be a minimum GU10 number of lights that would not need a Fibaro dimmer 2 ? I have a number of circuits with GU10 lights 6W X 9 in a kitchen and out in a hallway 2 way circuits of 2 each by 2 and a circuit of 4. Would I need a dimmer bypass then for all circuits. View answer
Asked 9 ´years ago | Z-Wave Fibaro Universal Dimmer 2
Hi - when wired this into a double switch and then included this with a Vera Plus controller there were 3 devices created - the master and 2x appliance modules. In Vera only using the master switch has an affect and it only controls one of the switches. How do I include this so that both switches are controlled? View answer
Asked 9 ´years ago | Z-Wave Fibaro Double Switch 2
Is this compatible with Home Assistant?
Asked 9 ´years ago | Z-Wave Fibaro Button
I want to use a Fibaro relay to swicth an immersion heater on and off. The load is switched using a double pole relay. Can I simply connect the Fibaro output across the relay energising contacts, or will you need a resistor in series to reduce the current? View answer
Asked 9 ´years ago | Z-Wave Fibaro Double Switch 2
Is this device suitable for switching 230V LED lights, or would it be better to use the double relay switch instead? Since it doesn't have dry contacts, I'm wondering if the LEDs may flicker while switched off (as is the case for the dimmer module). View answers
Asked 10 ´years ago | Z-Wave Fibaro Double Switch 2
Will this work outside as a motion detection? View answers
Asked 10 ´years ago | Z-Wave Fibaro Multi Sensor
I look at the instruction manual for the wiring diagrams. I have two wires coming from the wall and it has no wall switch. When I moved in, it had a cheap strip light with shaver socket and its own onboard switch. I have removed this old fitting. I am planning to install an LED strip light running off 12V. I wish to use the Fibaro Dimmer 2 with bypass 2. When I look at the wiring diagram for a 2 wire setup, it assumes I will have a Wall Switch. This makes the diagram useless to me. Can anybody help with an adjusted diagram please? View answer