I have a fused Switch controlling a fan and want to use this controller to operate the fan remotely as well as enabling the fused switch to continue controlling the fan at the wall, is there a wiring diagram showing how to achieve this? View answers
Asked 7 ´years ago | Z-Wave Plus Aeotec Nano Switch On/Off Controller
Hi. Has anyone had a good experience with these? The concept is great, but not if it doesn't work! Is it the firmware that is unstable, or the controller software? Have the Vesternet staff had any experience with them? Also, are they always listening, or do they have a wake up period? Thanks, Ed View answers
Asked 7 ´years ago | Z-Wave Fibaro Heat Controller
Is it fully compatible with Vera ? View answer
Asked 7 ´years ago | Z-Wave Fibaro Radiator Thermostat Starter Pack
I have a Homeseer setup and have bought the Fibrao FGS 223. I have managed to include it but want to change the default toggle to momentary switch as that's what I have elsewhere [legacy X10]. I tried Setting Parameter 20 to 0 in homseer z-wave node but it just says error and dosent change. Any help please View answer
Asked 7 ´years ago | Z-Wave Fibaro Double Switch 2
Hi Folks. Is it feasible to use this sensor to control your central heating. If I used a fibaro relay to control the boiler could the temperature sensor be used as a thermostat to set or monitor the temperature or would I need to buy a dedicated Zwave thermostat? Any advice would be greatly appreciated. View answer
Asked 7 ´years ago | Z-Wave Fibaro Multi Sensor
Asked 7 ´years ago | Z-Wave Philio Motion Sensor PSP05 with Round Recessor - Gen5
Does it disconnect the neutral line as well ? View answer
Asked 7 ´years ago | Z-Wave Plus Secure Wall Switch
This installed with 4 SES002 and paired to Vera Edge. Vera reports the correct ambient temp agains the first sensor but all 4 pipe sensors report "-327.68 °". Ive checked all the connections, removed and reattached from the Zwave network etc but stays same. What can you suggest pls View answers
Asked 7 ´years ago | Z-Wave Plus Secure SES302 Temperature Sensors Gen5
How does the thermostat in a room that is too cold turn the boiler on so that the radiator can be supplied with hot water. You can’t leave the boiler set on permanently. In most UK central heating systems there is a central thermostat and or programmer that determines when the boiler switches on or off. View answers
Asked 7 ´years ago | Z-Wave Fibaro Heat Controller
Asked 8 ´years ago | Z-Wave Fibaro Multi Sensor
Can the connection lead be extended? I would install 2 units, one for internal temperature the other extended to approx 4m for external temperature, only the last bit of the of the extended one would need to be waterproof. View answers
Asked 8 ´years ago | DS18B20 Digital Thermometer - Waterproof 1m
Where is the Aeotec bypass? Aeotec's website still says that it will be available "early 2017", and yet here we are here in September and I cannot see much evidence of its availability. Does anyone have any insights into when it will be available? Thanks. View answer
Asked 8 ´years ago | Z-Wave Plus Aeotec Nano Dimmer
Hi all, I have installed a couple of these (fgs223) on a 2 way switch. One is an on off switch and the other is a dimmer. I've put the switches behind the on off switch. That bit works well but now the separate dimmer won't dim it only switches on and off. Any suggestions? View answers
Asked 8 ´years ago | Z-Wave Fibaro Double Switch 2
Z-Wave Fibaro KeyFob working with the Vera plus ?
Asked 8 ´years ago | Z-Wave Fibaro KeyFob
Hey, will it work with the Vera Plus?
Asked 8 ´years ago | Z-Wave Philio 2 * 1.5 KW Relay Inserts
Hi there, I'm looking for a Z-wave dry contact switch, connected to my existing pilot wires from the boiler. Not really fussed about it being a thermostat, as all I need is to be able to remotely turn the heating on or off. I don't want to have to change out anything with the existing boiler's timer / programmer. I intend to leave it heating turned on at the boiler indefinitely, and the dry contact switch as the main on-off. I can then use scenes to control timing if need be. I don't think this Secure product is built for that since it needs replacing the boiler's timer / programmer. Can you kindly recommend a suitable product? Thanks in advance. View answers
Asked 8 ´years ago | Z-Wave Plus Secure Wall Thermostat with LCD display
Is this suitable for powering a Zipabox controller?
Asked 8 ´years ago | 12V 30W Interchangeable Power Supply
Can this be used with the 2 channel boiler receiver? If so, how does it manage the hot water channel? I have a Razberry but wanted this to manage in the case of its failure (and because I understand it will manage the boiler better?) View answers
Asked 8 ´years ago | Z-Wave Plus Secure Wall Thermostat with LCD display
I think I need this, since my LED lamp still glows a bit when it should be off, but am not clear on how it is meant to be fitted. The wiring diagram in the manual is hopeless - so do you have to put this inside the light fitting somehow ? I don't see where it would physically go, to bridge across the bulb. There are two lights driven by the same switch, so do I need to bypass them both ? View answers
Asked 8 ´years ago | Z-Wave Fibaro Dimmer Bypass 2
Is this Controller working with vera plus? View answer
Asked 8 ´years ago | Z-Wave Qubino Flush Shutter Plus